校准设备
Calibration is an essential step in every precision measurement. It establishes the relationship between the sound pressure and the electrical output of the microphone.
Calibration can be performed at either 250 Hz or at 1 kHz. Both frequencies have their advantages and disadvantages.
250 Hz is in the frequency range where the frequency response of almost all microphones is flat and will therefore give the most accurate calibration.
If, however, the microphone is used in connection with measuring equipment with weighting filters, for example a sound level meter with A-weighting, the 250 Hz signal will be attenuated by the weighting network. In this case it might be advantageous to use a 1 kHz calibration frequency.
At 1 kHz, the weighting filters have 0 dB attenuation and will therefore not affect the calibration.
On the other hand, since the frequency response of the microphone is not flat, a small error could be introduced.
Freq range:
ANSI: S.1.40, S.1.43, S.1.11, S.3.6
IEC: 60318-1 & -2
GRAS 90AA Audiometer Calibration System Equipment
The GRAS 90AA Audiometer Calibration System is easy and fast to set up and control and can be upgraded as your calibration needs change. From quick measuring of frequencies and test signal levels to harmonic distortion and representation of the values in one table together with the third octave band spectrum.
Freq range:
ANSI: S.1.40, S.1.43, S.1.11, S.3.6
IEC: 60318-1 & -2
GRAS 90AB Basic Audiometer Calibration System
The GRAS Audiometer Calibration Systems are configured to meet the requirements of modern audiometer calibration. They are easy and fast to set up and control, and can be upgraded as your calibration needs change.
GRAS 90CA-S2 Microphone Calibration System Equipment, PXI
The GRAS 90CA-S2 Microphone Calibration System provides for automated and reliable level and frequency response calibration of measurement microphones. The implemented calibration methods conform with relevant standards as listed in the specifications.
Freq range: 1 Hz to 200 kHz
IEC: 61094-6
GRAS 14AA Electrostatic Actuator Amplifier
The GRAS 14AA Electrostatic Actuator Amplifier is a high-gain, high-voltage amplifier. The 14AA together with the available GRAS electrostatic actuators RA0014 and RA0015 comply with IEC 61094 -6 “Measurement microphones - Part 6: Electrostatic actuators for determination of frequency responses.”
GRAS OP0024 Kit for Frequency Calibration of Flush-mount Microphone Sets
The GRAS OP0024 kit contains a calibration holder, electrostatic actuator and actuator calibration adapters for 1/8" and 1/4" size of GRAS Flush-mount Microphone Sets. For 1/2" size no adapter is used.
GRAS OP0026 Kit for Frequency Calibration of 1/4" Surface Microphones
The GRAS OP0026 kit contains an electrostatic actuator and an actuator calibration holder for GRAS precision 1/4" surface microphones.
GRAS RA0014 1/2'' Electrostatic Actuator
The GRAS RA0014 1/2'' Electrostatic Actuator is an electrostatic actuator for testing the frequency response of standard 1/2”, 1/4” and 1/8" microphones; adapters are included for testing 1/4” and 1/8"microphones. The GRAS RA0014 can be connected directly to the GRAS 14AA Actuator Supply .
GRAS RA0014-S1 1/2'' Electrostatic Actuator for 40AU-1
The GRAS RA0014-S1 1/2'' Electrostatic Actuator is for testing the frequency response of the microphone 40AU-1. The GRAS RA0014-S1 can be connected directly to the GRAS 14AA Actuator Supply .
GRAS RA0015 1'' Electrostatic Actuator
The GRAS RA0015 is an electrostatic actuator for testing the frequency response of standard 1” microphones. The RA0015 can be connected directly to the GRAS 14AA Actuator Supply.
Sound pressure level: 140 dB
Freq range: 0.01 to 250 Hz
GRAS 42AE Low Frequency Calibrator
The GRAS 42AE Low-Frequency Calibrator permits microphone calibration at frequencies down to 0.01 Hz for both front and rear-vented microphones. It produces a constant sound pressure level down to very low frequencies.
Freq range: 50 Hz to 6.3 kHz
ANSI: S1.10
IEC: 61043
GRAS 51AB Phase Calibrator according to IEC 61043
The Sound-intensity Calibrator 51AB is a coupler for phase and level calibrations of sound-intensity microphone pairs. It can be used for residual intensity testing, sound-intensity level calibration and particle velocity calibration as specified in IEC standard 1043 Electroacoustics-Instruments for the measurements of sound intensity- Measurement with pairs of pressure sensing microphones.
Freq range: 2.5 Hz - 200 kHz
Noise: 1.8 µV
Gain: -0.25 dB
Special feature: Insert voltage for determining open-circuit sensitivity of a microphone
GRAS 26AG 1/2'' Insert Voltage Preamplifier with Integrated Connector
The GRAS 26AG is a small robust preamplifier with insert voltage calibration facility. It has a very low inherent noise level, a wide dynamic range and a frequency response from below 2 Hz to above 200 kHz.
Freq range: 2.5 Hz - 200 kHz
Noise: 1.8 µV Gain: -0.29 dB
Special feature: For open-circuit sensitivity calibration of 1/2" and 1/4" microphone cartridges
GRAS 26AN 1/4'' Insert Voltage Preamplifier
The GRAS 26AN 1/4" Preamplifier is a small robust unit optimised for acoustic measurements using condenser microphones. It has a very low inherent noise level, a wide dynamic range and a frequency response from below 2 Hz to above 200 kHz.GRAS 26AN is configured to permit use of the insert voltage-technique for determining the open-circuit sensitivity of a microphone.
Sound pressure level: 114 dB
Frequency: 250 Hz
IEC: 60942
GRAS 42AA Pistonphone, Class 1
The GRAS Pistonphone 42AA is a battery-operated, precision sound source for accurate and reliable calibration of measurement microphones, sound level meters, and other sound measuring equipment.
Sound pressure level: 134 dB
Frequency: 250 Hz
ANSI: S1.40
IEC: 60942
GRAS 42AC Pistonphone, high pressure, Class 1
The GRAS 42AC Pistonphone, high pressure is a precision sound source for calibrating microphones. It is battery operated and produces a constant sound pressure level of 134 dB re. 20µPa (equivalent to 100 Pa) at 250 Hz, or 125.4 dBA re. 20µPa.
Sound pressure level: 114 dB
Frequency: 250 or 251.2 Hz
ANSI: S1.40
IEC: 60942 (2018) LS
GRAS 42AP Intelligent Pistonphone Class 0
The GRAS 42AP Pistonphone is a battery-operated, precision sound source for accurate and reliable calibration of measurement microphones, sound level meters and other sound measuring equipment.
Standard: IEC 61043
Special feature: Calibration coupler with two matched calibration chambers for GRAS Rugged Intensity Probes.
GRAS 51AC Sound Intensity Calibration Kit
The 51AC Sound Intensity Calibration Kit is a ready to use kit for sensitivity and phase calibration of GRAS Rugged Intensity Probes (50AI-LP, 50GI-P, 50GI-RP). The kit consists of a calibration adapter with two calibration chambers, a GRAS 42AA Pistonphone, Class 1, and a GRAS ZC0002K Barometer.
Sound pressure level: 94 dB or 114 dB
Frequency: 250 Hz or 1 kHz
ANSI: S1.40
IEC: 60942 class 1
GRAS 42AG 多功能声音校准器,1 级
GRAS 42AG多功能声音校准器是一种便携式、电池供电的精密传声器校准器。校准器可以直接用于1英寸传声器。包括用于校准1/2英寸(工厂安装)、1/4英寸和1/8英寸传声器的适配器。
<meta charset="utf-8" />
For in-situ verification of surface-mount and flush-mount microphones
GRAS RA4800 Adapter for Sensitivity Verification of Flush/Surface Microphones
RA4800 is a field verification adapter for UTP, surface-mount, and flush-mount microphones. With this adapter, it is possible to perform quick and reliable verification without having to dismount the microphone.